Specifications
S83/85 Ultrasonic Generator System Installation
A40-064 Rev 0 Page 55
5.8.6 Wiring Three FC Immersible Transducers (36 elements shown)
Figure 5-19 Wiring Three FC Type Immersible Transducers
ID Label
RF Cable
S8XXX − XX
J1
Assembly
S8000 RF Cable
Wiring Diagram
− −
(BLK)
Transducers
Immersible
+ +
(RED)
(GRN/YEL)
3
(BLK)
J1
J1
2
1
3
1
2
(RED)
J1
−
+
(RED)
(RED)
(BLK)
(BLK)
To Immersibles
SS Overbraid
Flexible Conduit (3)
RF+ (RED)
RF− (BLK)
GND (GRN/YEL)
RED
JUMPER
BLACK
JUMPER
Note: After installing, test grounds and continuity according to local codes.










