Instructions / Assembly

Table Of Contents
Page 13 of
17
Using Your Fire Table
1.
Make sure the Control Knob (11) is in the “OFF” position.
2.
Open the Door and slowly open the Valve (22) on the Propane Gas
Tank by turning the Contol Knob (11) counterclockwise.
3.
Close the Door on the Main Frame (04) of the Fire Table.
4.
Push and hold in the Electronic Ignitor (12) to create sparks within the
electrode continue to hold.
5.
Push in the Control Knob (11) and turn to the “LOW” position.
Keep holding down the Control Knob (11) to allow gas to flow for 15
seconds.
6.
If ignition doesn’t occur within a few seconds release the Control Knob
(11) and rotate to the “OFF” position.
Wait for 5 minutes for gas to clear and then repeat the above lighting
instructions.
7.
Once the Fire Table / Column is lit, the flame intensity may be
controlled by turning the Control Knob (11) between the “LOW” and
“HIGH” positions
Operation
NOTE: Whenever gas connections are loosened or removed, you must
perform a complete leak test. Complete installation.
8.
Observe flame height when lit:
1) Flame color should be yellow / blue.
2) Flame height burns at 2 - 10 inches high.
2 inches to 10 inches