Spec Sheet

Table Of Contents
Architectural Specifications
The universal auto changeover thermostat shall be a Braeburn
®
model number 5220, 3.86” high x 5.11” wide x 1.42” deep, powered with either 24 Volt AC or with two
“AAAlkaline batteries (3.0 Volt DC). In the event of a power failure, the unit shall retain all user, installer and program settings. The thermostat shall be compatible with
low voltage single stage or multi-stage gas, oil, or electric conventional heating or cooling systems with up to two stages of heating and two stages of cooling, and heat
pump systems with up to three stages of heating and two stages of cooling. Also compatible with 250mv – 750mv millivolt heating only systems
and 2 or 3 wire hydronic
zone systems.
The thermostat shall have a bright blue backlight display, SpeedBar
®
, separate sub-base and multi-level keypad lockout. Temperature control range shall
be between 45° and 90° F (7° and 32° C), accuracy of +/- 1° F (+/- .5° C). Operating humidity range between 5% and 95% relative humidity. The thermostat shall include
separate installer and user setup modes, residential or commercial setup modes, permanent non-volatile memory to retain user settings, filter, UV and humidifier pad
check monitor, adaptive recovery mode (ARM
), programmable fan mode, residual cooling fan delay, indoor or outdoor remote sensor capability, auxiliary heat fossil fuel
programming, and compressor power outage protection. A front reset button will return user settings to default values when pressed.
Meets Energy Aware
®
Guidelines.
©2017 Braeburn Systems LLC • All Rights Reserved • 5220-300-07
Product Specifications
Dimensions: 3.86” x 5.11” x 1.42”
Electric Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
5 amp total maximum load (all terminals)
AC Power: 18-30 Volt AC
DC Power: 3.0 Volts DC
(2 “AA” Alkaline batteries included)
Compatibility: Heat pump systems up to 3 heat/2 cool,
Conventional systems up to 2 heat/2 cool
250mv – 750mv millivolt heating systems
Control Range: 45° to 90° F (7° to 32° C)
Display Range: 40° to 99° F (5° to 37° C)
Accuracy: +/- 1° F (+/- .5° C)
Temperature
Differential:
1st Stage - .5°, 1°, or 2° F (0.2°, 0.5°, or 1° C)
2nd and 3rd Stage - 1°, 2°, 3°, 4°, 5°, or 6° F
(.5°, 1°, 1.5°, 2°, 2.5°, or 3° C)
Storage Temperature: 14° to 140° F (-10° to 60° C)
Operating Humidity: 5% to 95% Relative Humidity
Terminations: G, Rc, Rh, W2, O/B/V3, Y1, Y2, W1/E/W3,
C, L, S1, S2
Accessories
2920 Vertical J-Box Adapter Wall Plate
2950 Universal Wall Plate (6.5” x 6.5” x .125”)
5970 Universal Thermostat Guard
Shipping Information
INDIVIDUAL CARTON MASTER CARTON
Dimensions: 5.0” x 6.3” x 2.0” Quantity: 6
Weight: .92 lbs. Dimensions:
6.4” x 13” x 5.6”
Cubic Feet: .27
Weight: 6 lbs.
Braeburn 5220 Replaces*
Honeywell
®
TH6220D, TH6220U, TH6320D
Emerson
®
1F85-0477, 1F85U-421PR, 1F95-0671, 1F95EZ-0671
*Verify specific application requirements.
All trademarks are the property of their respective owners.
FREE Contractor Branding Available!
Visit our website (www.braeburnonline.com) for more information, contact your
local distributor or call our sales department toll-free at 866.268.5599 (U.S.),
+1.630.844.1968 (Outside the U.S.).
Terminal
Designations
G Rc Rh W2 O/B/V3 Y1 Y2 W1/E /W3 C L S1 S2
1st Stage Conventional
Heat / Emergency /
3rd Stage Heat
Cooling
Transformer
Date: _____________________________________________
Job Name: _________________________________________
Location: __________________________________________
Contractor: ________________________________________
Engineer: __________________________________________
Model No.: _________________________________________
Submitted By: ______________________________________
Submitted For Approval: ___________ Record: ___________
Fan Output
Heating
Transformer
1st Stage
Compressor Output
2nd Stage
Compressor Output
Transformer
Common
Heat Pump
Check Input
Remote Sensor
(Indoor or Outdoor)
5390 Remote Indoor Sensor
5490 Remote Outdoor Sensor
Braeburn Systems LLC • 2215 Cornell Avenue • Montgomery, IL 60538 • Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.)
2nd Stage Conventional
Heat / Auxiliary Heat
Reversing Valve or
Zone Valve Power Close
®