Installer Guide

Installer Guide 4
Wiring Terminations for model 5220
Terminal Function Description
  Rc Input 24VoltACCoolingTransformer
(DualTransformerSystemsOnly)
Rh Input PowerConnection(24VoltACHeating
TransformerorMillivoltPowerSource)
G Output FanControl
W1/E/W3 Output (W1)1stStageConventionalHeat,
  (E)EmergencyHeat,
(W3)3rdStageAuxiliaryHeat
 W2 Output 2ndStageConventionalHeat
O/B/V3 Output (O)CoolActiveReversingValve
(B)HeatActiveReversingValve
(V3)ZoneValvePowerClose
  Y1 Output 1stStageCompressor
  Y2 Output 2ndStageCompressor
  L Input SystemMalfunctionIndicator
C Input 24VoltACTransformerCommon
  S1
  S2
Connecting Your Wires (continued)
3
Input OptionalRemoteSensor(indoororoutdoor)