Install Instructions

FAN CALLS
Number of fan calls currently being serviced. Check the panel
LED if it is necessary to determine exactly which zones are
16
Equipment Plenum Temperature (PLENUM TEMP)
When the optional plenum air temperature sensor is installed and
enabled, the zone panel will display the Plenum temperature in
the range of 30 - 200˚ F (1 - 93˚C).
Plenum Temperatures outside
this range indicate an equipment error.
See Section 7 Error
Conditions for a further explanation.
NOTES: When no zones are calling, the panel will command
all dampers to open.
For maximum energy conservation, a purge will occur at the
end of each call.
No calls will be answered until the purge is complete.
Dampers will not close if the plenum temperature sensor is not
connected or is not functioning properly.
Emergency Heat Selection (Multi-stage Heat Pump Systems Only)
Emergency Heat can be selected at the main panel or from a Heat
Pump Thermostat wired to the main panel. No cooling calls will be
answered if emergency heat is switched on.
To select Emergency Heat from the main panel:
1. Press and release the EM HEAT button located below the main display.
2. The display will update from HEAT CALLS to EM HEAT CALLS and will show COOL DISABLE to indicate that
no compressor calls will be answered.
3. To stop Emergency Heat, press the EM HEAT button again.
4. The display will update from EM HEAT CALLS to HEAT CALLS and COOL CALLS will return.
To select Emergency Heat from a thermostat
1.
Set Emergency Heat Thermostat to Emergency Heat switch position (only one thermostat can
control Emergency Heat)
2. Raise heat setting on Emergency Heat Thermostat to create Emergency Heat call.
3. The zone panel display will update from HEAT CALLS to EM HEAT CALLS and will show COOL DISABLE to
indicate that no compressor calls will be answered.
4. To stop Emergency Heat, set the Emergency Heat Thermostat to a non-emergency heat position or
lower the temperature on the Emergency Heat Thermostat to end the emergency heat call.
5. The zone panel display will update from EM HEAT CALLS to HEAT CALLS and COOL CALLS.
NOTE: Configuration setting number 22 in section 4 selects which thermostat is used to activate Emergency Heat.