User's Manual

15 Installer Guide
26 Humidification Mode [note 12]–Forusewithanexternalhumidier.Selectsbetweendisabling
humidication(OFF),dependentcontrol(DEP)orindependentcontrol(IND).TheDEPsettingcontrols
humidicationonlyduringacallforheating.TheINDsettingallowshumidicationoutputintheheatmode,
butdoesnotrequireacallforheating.NOTE: It is recommended that the IND setting only be used with
systems designed for low air temperature humidification such as steam humidification. Always ensure the
heat exchanger or other system parts are not exposed to excess water from condensation or other sources.
When there is any doubt, use the OFF or DEP setting.
27 Auto Humidity Set Point Limit [notes 11, 12]–Selectbetweenturningtheautomatic
humiditysetpointlimittoauto(AUTO)ormanual(MAN).WhenAUTOisselected,humiditycontrolisprovided
automaticallybasedontheoutdoortemperature.SelectingMANallowsyoutomanuallycontrolthelevel
ofhumidity.
28 Dehumidification [note 12]–Forusewithanexternaldehumidier.Selectbetweendehumidication
disabled(OFF),anormallyinactive(NI)ornormallyactive(NA)relay,dependingontherequirementsofyour
externaldehumidicationequipment.
29 Installer Clear–Clearssettingsbasedonyourselection.CLROmakesnochanges,CLR1clearsall
wirelessremotesensorconnections,CLR2clearstheconnectiontothecontrolmoduleandCLR3clearsALL
thermostatsettings.
WARNING:IfyoupressNEXT or RETURNafterselectingCLR1,CLR2orCLR3theclearwilltakeplaceand
theappropriatesettingswillbereturnedtofactorydefaults.Ifyoudonotwishtomakeanychanges,usethe
SpeedBar
®
toselectCLRO.