DAY/TIME
7 Installer Guide
3) InsertQuickReferenceCardintoslot
ontopofthermostat.
Pairing the Thermostat and Control Module
1. Onthethermostat,pressandholddowntheHOLD and
RETURNbuttonsfor3seconds.
2.ThewordCMOD(controlmodule)willappearinthe
displayandthesymbolwillash(seeFigure1).
3.Onthepoweredcontrolmodule,pressandholdthe
CONNECTbuttonfor3seconds(seeFigure2).
4. Thecontrolmodulewillenterpairingmodefor60
seconds.DuringthistimetheblueCOMM indicator on
thecontrolmodulewillashonceevery2seconds.
5.Oncesuccessfullypaired,thesymbolwillstop
ashingandtheblueCOMM indicator on the control
modulewillturnon.
6.PressRETURNonthethermostatatanytimetoexit.
NOTE: In step 2, if the control module has already been
paired, the symbol will not be flashing.
Replacing a Thermostat
Ifyouarereplacingathermostatthatispairedwithanexisting
controlmodule,youwillneedtoclearthecontrolmoduleand
pairitagainwiththenewlyinstalledthermostat.
1.Installthenewthermostat.
2.Onthecontrolmodule,pressandholdtheCONNECTbutton
for10secondsuntiltheredCOMM indicator turns on.
3.ReleasetheCONNECTbuttonandtheblueandredLEDwill
eachashoncetoindicatethecontrolmodulewas
successfullycleared.
4.Pairthenewthermostatwiththecontrolmodule.
Replacing a Control Module
Ifyouarereplacingacontrolmodulethatispairedwithanexistingthermostat,youwillneedtoclearthe
thermostat’scontrolmodulesettingsbeforepairingthenewwirelesscontrolmodule.
1.Installthenewcontrolmodule.
2.ThermostatcontrolmodulesettingsareclearedbyadjustingInstallerSetting#29to CLR2.Thissettingclears
theconnectionbetweenthethermostatandcontrolmodule(see section 4).
NOTE: Be careful not to select CLR3 unless you want to clear all the thermostat settings.
3.Pairyournewcontrolmodulewiththethermostat.See“PairingtheThermostatwithControlModule”.
Communication Loss
Ifcommunicationbetweenthethermostatandcontrolmoduleislost,theredCOMM indicator on the control
modulewillbegintoashonceevery10seconds.Thecontrolmodulewillattempttoreconnecttothethermostat
severaltimesautomatically.
NOTE: To attempt to reconnect manually, press and hold the CONNECT button for 3 seconds.
ThethermostatdisplaywillalsoindicatethatcommunicationhasbeenlostbyashingCOMM LOSS CMOD.
Duringcommunicationlossthereturnairsensorisusedtomaintainthefactorydefaultheatingandcooling
temperatures.
6
Pairing the Thermostat with Control Module
Figure1
Connect
Button
Figure2
PWR
COMM