Wireless Remote Sensor Communication Loss
Ifcommunicationbetweentheremotesensorandthermostatislost,theredindicatorontheremote sensor
willbegintoashonceevery10seconds.Thesensorwillattempttoreconnecttothethermostatseveral
timesautomatically.
NOTE: To attempt to reconnect manually, press and hold the CONNECT button for 3 seconds.
Thethermostatdisplaywillalsoindicatewhichwirelessremotesensorhaslostcommunicationbyashing
COMMLOSSalongwiththeremotesensorthathaslostcommunication(seeTable2).
Wireless Remote Sensor Low Battery
Ifthebatteriesinawirelessremotesensorarelow,theredindicatorwillash3timesevery30seconds.The
thermostatdisplaywillalsoindicatewhichwirelessremotesensorhasalowbatterybyashingLOWBATT
alongwiththeremotesensorthathasthelowbatterycondition(seeTable2).Replacetheremotesensor
batteriesimmediately.
NOTE: After replacing batteries, allow up to 15 minutes for the wireless connection to re-establish.
IDS1, IDS2, IDS3 or IDS4 RemoteIndoorSensor1-4
HMS RemoteHumiditySensor
ODS RemoteOutdoorSensor
Warning
Read Before Testing
• Donotshort(orjumper)acrossterminalsonthegasvalveorattheheatingorcoolingsystemcontrolboard
totestthethermostatinstallation.Thiscoulddamagethethermostatandvoidthewarranty.
• DonotselecttheCOOLmodeofoperationiftheoutsidetemperatureisbelow50ºF(10ºC).Thiscould
possiblydamagethecontrolledcoolingsystemandmaycausepersonalinjury.
• Thisthermostatincludesanautomaticcompressorprotectionfeaturetoavoidpotentialdamagetothe
compressorfromshortcycling.Whentestingthesystem,makesuretotakethisdelayintoaccount.
NOTE: The compressor delay can be bypassed by pressing the reset button on the front of the thermostat.
All user settings will be returned to factory default, however all Installer settings will remain as originally
programmed in section 4.
1 PressSYSTEMuntilthethermostatisinHEATmode.
2 UsingtheSpeedBar®raisethesettemperatureaminimumof3degreesabovethecurrentroom
temperature.Thesystemshouldstartwithinafewseconds.Withagasheatingsystem,thefanmay
notstartrightaway.
3 PressSYSTEMuntilthethermostatisintheOFFmode.Allowtheheatingsystemtofullyshutdown.
4 PressSYSTEMuntilthethermostatisintheCOOLmode.
5 UsingtheSpeedBarlowerthesettemperatureaminimumof3degreesbelowthecurrentroom
temperature.Thesystemshouldstartwithinafewseconds(unlesscompressorshortcycleprotection
isactive–Seenoteabove).
6 PressSYSTEMuntilthethermostatisintheOFFmode.Allowthecoolingsystemtofullyshutdown.
7 PressFANuntilthethermostatisinFANONmode.Thesystemfanshouldstartwithinafewseconds.
8 PressFANuntilthethermostatisinFANAUTOmode.Allowthesystemfantoturnoff.
9 Ifthethermostatiscontrollingauxiliaryequipmentsuchasahumidier,adjustthethermostat
settingstotestthesedevices.
6
System Testing
Table 2