User`s manual

TLS PC Link
TM
Programmer’s Guide
42
Example 3 (0.24” continuous terminal block material, PTLTB-400-
240):
To print a terminal block label, it is necessary to set the label size and spacing. In
order to obtain this spacing, the printer must not be fed to the cut position
between terminal block positions on the label. The <STX>C command is used to
disable this function. This example is for a terminal block with a 0.5” pitch.
+5V +5V +5V GND GND GND GND GND GND +12V +12V +12V
<STX>n ;put printer in inches mode
<STX>P0050 ;set label length to 0.5”
<STX>S0000 ;set spacing to zero
<STX>C ;disable feed to cut after print
<STX>L ;enter label format mode
490000700450004+12V<CR> ;place +12V, rotated 270
degrees at
;location X=0.04”, Y=0.45”
X<CR> ;exit label format mode
<STX>E0003 ;set quantity to 3
<STX>G ;print 3 copies of this label
<STX>L ;enter label format mode
490000700400004GND<CR> ;place GND, rotated 270
degrees at
;location X=0.04”, Y=0.40”
X<CR> ;exit label format mode
<STX>E0006 ;set quantity to 6
<STX>G ;print 6 copies of this label
<STX>L ;enter label format mode
490000700400004+5V<CR> ;place +5V, rotated 270 degrees
at
;location X=0.4”, Y=0.40”
X<CR> ;exit label format mode
<STX>E0003 ;set quantity to 3
Y
X