User`s manual
TLS PC Link
TM
Programmer’s Guide
39
Method 1 (New label format):
<STX>L ;enter label format mode
1Y0000000250000brady<CR> ;specify brady image at
X=0.00”,Y=0.25”
1Y0000000100082logo<CR> ;specify logo image at
X=0.82”,Y=0.10”
190000600700005PART NUMBER:<CR> ;specify text at X=0.05”,Y=0.70”
190000600950005DESCRIPTION:<CR> ;specify text at X=0.05”,Y=0.95”
190000601200005QUANTITY:<CR> ;specify text at X=0.05”,Y=1.20”
190000600700100
56789
<CR>
;specify text at X=1.00”,Y=0.70”
190000600950100LABEL<CR> ;specify text at X=1.00”,Y=0.95”
190000601200100100<CR> ;specify text at X=1.00”,Y=1.20”
X<CR> ;exit label format mode
<STX>G ;print two labels
Method 2 (Update Field):
<STX>U06
56789
<CR>
;Replace field*
<STX>G ;print two labels
Note: The new field string “56789” must be the exact same length as the old
string “12345”. This field is number 06 because they are numbered in the order
they were entered in the label format, starting with 01.