Set Printer to Inches (STX n)
This command sets the printer to interpret measurements in inches in terms of
in./100, (e.g., <STX>M0500 will be interpreted as 5.00in.). See STX m.
Sample:
<STX>n
Default setting: Inches
Feedback possibilities: 0,1,2
Set Start of Print Offset (STX O)
This command sets the point where printing starts, relative to the top-of-form
position. Top-of-form is the point where a label edge is detected by the label
edge sensor. The printer will feed from the top-of-form to the offset point
specified in this command, and begin printing there. This offset value is
independent of the STX f, set form stop position command.
<STX>Osnn
Where:
s- sign of offset, ‘+’ or ‘-’
nn- two digit value of offset
The valid range is -05 to +99.
Sample:
<STX>O+05
The above sample sets a start of print position of 5 pixels after the default
position.
Feedback possibilities: 0,1,2