User guide
Bradyprinter THT MVPplus Quick Reference Guide
Position the Transmissive Sensor
English 13293LB-12 Rev. 2 16Nov2004 EN-7
To adjust the transmissive sensor:
1. Press the printhead open lever.
The printhead assembly springs up. Continue to pivot the printhead until it locks into
place.
2. See Figure 4. Locate the transmissive sensor.
3. Push the sensor sleeve all the way in on the transmissive sensor.
4. See Figure 5. Locate the white adjustment tab pointer on the back of the transmissive
sensor.
5. What type of media are you using?
6. Ensure the media and ribbon are properly positioned.
7. Close the printhead assembly.
If you are using… Then…
Non-continuous media
with notched edges
Move the adjustment tab pointer to the inner positioning
mark. The point of the tab should align with the mark.
Non-continuous media
without notched edges
Move the adjustment tab to the outer positioning mark. The
point of the tab should align with the mark.
Continuous media Move the adjustment tab to the outer positioning mark. The
point of the tab should align with the mark.
Note • Certain types of media may require you to position the adjustment tab to locations
outside of the sensor sleeve.