User guide
EN-8 13293LB-12 Rev. 2 16Nov2004 English
Bradyprinter THT MVPplus Quick Reference Guide
Position the Reflective Sensor
Position the Reflective Sensor
Refer to Figure 6.
1. Open the printhead assembly and turn on the AC power.
2. Locate the reflective sensor positioning lever.
3. For non-continuous media: Move the lever across the width of the media to align the
reflective sensor with the start-of-label indicator (notch, hole, black mark, or gap). The
glow of the red LED through the media helps to position the sensor.
4. For continuous media: Position the reflective sensor anywhere under the media so that a
“MEDIA OUT” condition can be sensed.
5. Ensure that the media and ribbon are properly positioned.
6. Close the printhead assembly.
Figure 6 • Position the Reflective Sensor
Note • This sensor is typically covered by a factory-installed plate. If you need to enable this
sensor, you must remove the plate.
Printhead
Transmissive
Sensor
Reflective
Sensor
Reflective Sensor
Positioning Lever