Service Manual PAM 3600 5 Adjustments
Adjusting the Sensor 1 Main Cylinder
The sensor checks if the main cylinder reaches its upper end position. If the sensor is adjusted exactly the
integrated LED is switched on.
1
2
3
Figure 5w Adjusting the sensor 1 main cylinder
1 Sensor
2 Screw
3 Holder
Switch off the compressed air.
Check the integrated LED.
The LED is switched on if the sensor (1) is adjusted correctly in the upper end position.
If the sensor (1) is not adjusted correctly, loosen the screw (2) of the holder (3), slide the holder until the LED is
switched on and tighten the screw (2).
Slide the manual valve on the applicator to the bleed position.
Move the cylinder manually and check if the LED is switched on and off correctly.
Repeat the adjustment if necessary.
Slide the manual valve on the applicator to the operate position.
Switch on the compressed air.