Service Manual PAM 36005 Adjustments
5.13 Pneumatic Setting of the Table
If there are problems with the table during operation the pressure of the table can be measured and adjusted to the
recommended value.
BLOW-
AIR
VACUUM
A
View A
LIFT
CYL.
BRAKE
TABLE
SUPPORT
AIR
PRINT
HEAD
ROTATE
CYL.
H5/06
8
6
4
2
0
16
14
12
10
200
150
100
50
psi
bar
1bar=0,1MPa
1 2 5 6 443
Figure 5t Setting the pressure on the table
1 Screw
2 Tube
3 Valve key table
4 Manometer
5 T-tting
6 Tube
Switch off the printer, switch off the compressed air.
Remove the cover.
Pull the tube (2) out of the valve of the table and push it into the push-in T-tting (5) of the manometer (4).
Push the tube (6) of the manometer (4) into the valve of the table.
Switch on the printer, switch on the compressed air.
Measure the value of the compressed air on the table.
If necessary set the compressed air value to the recommended value by turning the screw (1) on the valve.
The recommended value is 2 bar.
Switch off the printer, switch off the compressed air.
Restore the normal tube connection.
Mount the cover.