Service manual

63Printer Applicator System PAM 3600
Service Manual PAM 3600 5 Adjustments
5.12 Pneumatic Setting of the Supporting Air
If a blow tube is installed sometimes it is necessary to set the strength of the supporting air.
It is dependent from the size and the format of the label.
BLOW-
AIR
VACUUM
LIFT
CYL.
BRAKE
TABLE
SUPPORT
AIR
PRINT
HEAD
ROTATE
CYL.
1 2
Figure 5s Setting the strength of the supporting air
1 Screw
2 Valve key supporting air
Remove the cover.
Set the supporting air by turning the screw (1) on the concerning valve.
Check the supporting air on the blow tube by pressing the integrated key (2) of the valve.
Mount the cover.
1.
2.
3.
4.