Service manual

62 Printer Applicator System PAM 3600
Service Manual PAM 36005 Adjustments
5.11 Pneumatic Setting of the Brake
If there are problems with the brake during operation the pressure of the brake can be measured and adjusted to
the recommended value.
BLOW-
AIR
VACUUM
LIFT
CYL.
BRAKE
TABLE
SUPPORT
AIR
PRINT
HEAD
ROTATE
CYL.
1 2
3 2 54
Figure 5r Setting the pressure on the brake
1 Screw
2 Tube
3 Tube
4 T-tting
5 Manometer
Switch off the printer, switch off the compressed air.
Remove the cover.
Pull the tube (2) out of the valve of the brake and push it into the push-in T-tting (4) of the manometer (5).
Push the tube (3) of the manometer (5) into the valve of the brake.
Switch on the printer, switch on the compressed air.
Measure the value of the compressed air on the brake.
If necessary set the compressed air value to the recommended value by turning the screw (1) on the valve.
The recommended value is 2 bar.
Switch off the printer, switch off the compressed air.
Restore the normal tube connection.
Mount the cover.