5.4 Adjusting the Sensors of the Peel-off Table
After replacing a sensor ore after mechanical adjustments it is necessary to adjust the sensors of the peel-off table.
The correct adjustment of the peel-off table can be checked by watching the concerning LEDs on the applicator
control PCB. If one of the LEDs does not shine during the table movement the sensor has to be adjusted.
LIFT
CYL.
VACUUM
BLOW-
AIR
BRAKE
TABLE
SUPPORT
AIR
PRINT
HEAD
ROTATE
CYL.
1
2 3
Figure 5d Checking the LEDs
1 Valve key table
2 LED TIV
3 LED TIH
Remove the cover.
Release a movement of the table (4) by pressing the integrated key (1) on the concerning valve.
Check the LEDs (2, 3).
LED TIV (2) must shine if the front position of the table is adjusted.
LED TIH (3) must shine if the back position of the table is adjusted.
D-A93V
D-A93V
4
5 6
Figure 5e Setting the peel-off table position
4 Table
5 Upper sensor - front position
6 Lower sensor - back position
4. Loosen the screw on the concerning sensor (5, 6) by using a 1 mm screwdriver.
The upper sensor (5) recognizes the front position of the table. LED TIV (2) is shining.
The lower sensor (6) recognizes the back position of the peel-off table. LED TIH (3) is shining.
5. Shift the respective sensor (5, 6).
6. Release a movement of the table (4) by pressing the integrated key (1) on the concerning valve.
7. Check the LEDs (2, 3).
8. Repeat the adjustment if necessary.
9. Tighten the screw on the sensor if the table is adjusted correctly.
10. Mount the cover.