Service manual

46 Printer Applicator System PAM 3600
Service Manual PAM 3600
Sensors of the Applicator Module
1 1 1
Figure 4w Unscrewing the sensors of the applicator module
1 Sensors
Unscrew the respective sensor (1) by loosening the corresponding screw.
9135303_02
2
1
3
4
5
7
8
6
9
2 3
Figure 4x Replacing the sensors of the applicator module
2 Plug
3 Screw
2. Pull out the plug (2).
3. Remove the cover of the plug by loosen the screw (3).
4. Remove the concerning cable from the connector by loosen the respective screws.
5. Open the energy-chains if necessary (see section 4.13).
6. Replace the sensor and reassemble in reverse order.
7. Connect the printer to the power supply, switch on printer and compressed air.
8. Adjust the replaced sensor if necessary (see section 5.14).
1.
4 Replacing Assembly Units