Service manual
43Printer Applicator System PAM 3600
Service Manual PAM 3600 4 Replacing Assembly Units
Sensor transport locking roller
13 14
Figure 4s Preparation
13 Head plate
14 5 screws
Remove label stock and transfer ribbon from the printer.
Remove the cover.
Pull out the concerning plug (g. 4q, 7) on the CPU PCB (g. 4q, 6).
Loosen the ve screws (14) and remove the head plate (13).
Move the whole mounting forward.
View A
A
15 1516 17 18
Figure 4t Replacing the sensor transport locking roller
15 Screw
16 Bracket
17 Screw
18 Sensor transport locking roller
6. Loosen the two screws (15) on the bracket (16).
7. Take out the bracket with the mounted sensor.
8. Loosen the two screws (17) holding the sensor (18).
9. Replace the sensor and reassemble in reverse order.
10. Connect the printer to the power supply, switch on printer and compressed air.
1.
2.
3.
4.
5.