Operator`s manual

61
Step Operator Action Displayed Message Comment
13
Using the ‘Gain Number’
set in Step 12, complete the
following steps:
Place the label under the
Media Sensor. Record
the sensor reading and
label it “P” (paper).
Place the backing, mark,
or notch under the Media
Sensor. Record the
sensor reading and label
it “G” or “M” (gap or
mark).
Remove all media.
Record the sensor
reading and label it “E”.
-OR-
‘yyy’ is a
numerical value
representing the
current sensor
reading.
14
Press the key. And
then press the
key.
15
Press the
key.
Using the
or the
key set the ‘Paper’
level to the value
determined in the previous
step. Press the
key
to set the entry and advance
the menu.
Repeat for the ‘Mark’ or
‘Gap’ and ‘Empty’ levels.
-OR-
16
Press the key to
back out of the menu and
then press the
key
to save the settings and
return to the Main
Menu and
Ready Mode.
From Ready
Mode, press
and hold the
FEED key,
approximately
4 seconds, to
calibrate the