Operator`s manual
60
Step Operator Action Displayed Message Comment
11
Using the Gain Number
data collected from Steps 9
and 10, subtract each Label
Value from the TOF Value.
From the resulting list of
Difference Values, select
the largest number. Its
associated Gain Number is
the best selection for the
media. See example below.
-OR-
‘yyy’ is a
numerical value
representing the
current sensor
reading.
Both sensor
readings must
be above 20.
Gain Number Label Value TOF Value Difference Value
00 255 254 1
01 251 240 11
02 241 213 28
03 231 182 49
04 219 150 69
05 212 119 93
06 200 88 112
07 189 58 131
08 178 32 146
09 167 20 147
10 156 17 139
11 146 16 130
12 136 15 121
13 126 15 111
14 116 14 102
15 112 14 98
Example from the data compiled in the table above:
Gain Algorithm Number 8 should be used because it has the highest
difference value (146) where both label and TOF values are above 20.
Step Operator Action Displayed Message Comment
12
Using the
key,
select the Gain Number as
determined in Step 11.
Press the
key to
enable the entry.
-OR-
When enabled,
the selection
will be
indicated with
an *.
(Continued next page)