Datasheet
Product compliance information is based upon information provided by suppliers of the raw materials used by Brady to manufacture this product
or based on results of testing using recognized analytical methods performed by a third party, independent laboratory. As such, Brady makes no
independent representations or warranties, expressed or implied, and assumes no liability in connection with the use of this information.
Circuit Breaker Cross Reference Guide
Circuit Breaker
Manufacture
Breaker Type
# of
Poles
Circuit Breaker
Manufacture
Breaker Type
# of Poles
ABB
S501-B
1
ABB
S501UC-K
1
ABB
S502-B
2
ABB
S502UC-K
2
ABB
S503-B
3
ABB
S503UC-K
3
ABB
S501-C
1
ABB
S504UC-K
4
ABB
S502-C
2
Melin Gerin
B100A
2
ABB
S503-C
3
Melin Gerin
C80A
3
ABB
S501-D
1
Melin Gerin
NC100H
1-3
ABB
S502-D
2
Melin Gerin
NC125H
1-3
ABB
S503-D
3
Melin Gerin
NC100L
1-4
ABB
S501-K
1
Melin Gerin
100LH
1-4
ABB
S502-K
2
Melin Gerin
NC100L
3
ABB
S503-K
3
Melin Gerin
NC100N
1-4
ABB
S501UC-B
1
Siemans ITE
5SX11
1
ABB
S502UC-B
2
Siemans ITE
5SX21
1
ABB
S503UC-B
3
Siemans ITE
5SQ11
1
ABB
S504UC-B
4
Details:
MSDS Information
1. HAZARDS IDENTIFICATION
This product is NOT DANGEROUS and contains no hazardous ingredients
2. FIRST AID MEASURES/HEALTH INFORMATION PROTECTION
Eye Contact:
Not applicable, product is inert
Ingestion:
Not applicable, first aid is not normally required.
Inhalation:
Not applicable
Skin Contact:
Not applicable, product is inert, except if product is melted use gloves. For hot melted product, immerse in or flush affected area
with water to dissipate heat, then obtain medical attention.
Exposure Limits:
None
Threshold Limits
None
Personal Protection:
None (ambient conditions)
NPCA-HMIS Rating:
Health: 0; Flammability: 1; Reactivity: 0
NFPA-704 Rating:
Health: 0; Flammability: 1; Reactivity: 0
3. FIRE-FIGHTING MEASURES
● Be cautious of hot melted Nylon
● Use water spray to cool fire, exposed surfaces, and to protect personnel
● Isolate product from fire
● Respiratory and eye protection is required for fire fighting personnel
● Extinguish fire with water spray
● Decomposition products under fire conditions: Oxygen-lean conditions may
cause monoxide and irritating smoke
4. ACCIDENTAL RELEASE MEASURES
Land
Recover material and place in suitable container for reuse or for disposal in conformance with local regulations
Water
Recover material and place in suitable container for reuse or for disposal in conformance with local regulations.
5. HANDLING AND STORAGE
5.1 Handling
5.2 Storage