Troubleshooting guide
Bradley Washfountains Parts and Service Guide
40 Bradley Corporation • 215-1370 Rev. M; EN 08-003
1/7/08
THEN
Valve Position is Hot Supply Cold Supply Valve Delivers
Correct Hot Cold Mixed 107°
Correct Hot No Water Valve shuts off or drips
Correct No Water Cold Valve shuts off or drips
Correct Hot Hot Hot
Correct Cold Cold Cold
Reversed Hot Cold Cold/below 107° Hot/above 107°
Reversed Hot No Water Hot
Reversed No Water Cold Cold
Reversed Hot Hot Hot
Reversed Cold Cold Cold
Mixing Valve — Vernatherm
™
— Thermostatic (Prior to Aug, 2004)
*Repair kit S45-049 is pre-packaged and includes O-Ring, Flip Ring, Power Element and Spring.
Maintenance Instructions
1. Disassemble the Vernatherm™ Valve as shown,
being careful not to damage the power element.
Replace the element, if necessary.
2. If necessary, remove the old flip ring and replace
with a new ring.
NOTE: An old or worn flip ring may cause temperature
fluctuation and/or water chatter.
3. Reassemble the power element and valve body.
Apply grease to the main valve slide and gently ease
into position, rotating so that grease is applied to the
flip ring. Do not force the slide as this may push the
flip ring from its position. To test, rotate the slide; a
slight drag should be felt when correctly installed.
4. Reassemble the valve.
Service Suggestions
When servicing the Vernatherm™ valve, make sure it is installed in the correct position. The most
common error that occurs is when the valve is installed in the reversed position, that is, the hot line is
connected to the cold line and the cold is connected to the hot.
NOTE: A red ring is painted on the hot side of the valve.
The table below lists conditions that occur when the valve is installed correctly, and when it is in the
reversed position.
Flip Ring*
125-015
Power Element*
S27-019
Valve Slide
S01-039
Spring*
135-008
O-Ring*
125-001CH
Screw
160-175
Body
S73-027
Body (chrome)
S73-028
Cover
107-261B
IF