Installation manual
Terreon® Deep Bowl 36" Semi-Circular Washfountain with Air Metering Valve
TDB3103, WF3203 Installation Instructions
Bradley Corporation • 215-1479 Rev. G; EN 06-915
8 2/8/07
Installation Instructions continued . . .
Step 3: Installing drain spud in bowl
NOTE: Seal between drain spud and drain hole with plumber’s putty (supplied by installer).
1. Secure drain spud with lock nut and washers as shown in Figure 5.
Figure 5
Step 4: Supply Stop Valve,Tubing Connection, and P-trap Installation
NOTE: Flush supply lines before making connections.
1. Using pipe thread sealant, thread supplied 1/2" street elbows into the 1/2" angle supply stops
(see Figure 9, page 12).
2. Again using pipe thread sealant, thread supply stops onto stub-outs.
3. Follow the procedures below and refer to Figure 6 when installing 3/8" tubing into sprayhead to
ensure that you achieve a leakproof seal.
• Using a sharp knife, cut tubing squarely and remove any burrs. DO NOT pinch or crush end
of tubing.
• Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated.
Tighten nut to secure tube to fitting (make sure nut is securely tightened).
• If connector leaks, reseat tubing according to above procedure. If leaking persists,
replace male connector, or call your Bradley representative for assistance.
4. Connect P-Trap (supplied by installer) to tailpiece and drain outlet.
NOTE: Flush supply lines before making connections.
NUT
TUBING
MALE
3/8" TUBE
CONNECTOR
145-105
SPRAYHEAD
Figure 6
TUBING