Installation manual
Terreon® Deep Bowl 36" Semi-Circular Washfountain with Air Metering Valve
TDB3103, WF3203 Installation Instructions
Bradley Corporation • 215-1479 Rev. G; EN 06-915
6 2/8/07
Rough-In Specifications
CLEARANCE
TRAP FOR WALL OUTLET ONLY
- Supplies through wall
- Vent through wall
off-drain
1/2" NPT COLD SUPPLY THROUGH WALL
1/2" NPT HOT SUPPLY THROUGH WALL
1-1/2" NPT DRAIN
5" R. BOTTOM ACCESS
36" BOWL
(914)
HOLE
4"
(102)
2"
(51)
2"
(51)
1"
(25)
*12"
(305)
*17 - 21"
(432 - 533)
DRAIN THROUGH WALL
SUPPLIES THROUGH WALL
Type A Drain
(mm)
4-3/4"
(121)
NOTE: Supply lines for one to two
washfountains should be 1"; for three
washfountains, 1-1/4". For more than
three washfountains, pipe sizes should
be increased proportionately.
Figure 2
NOTE:
Drain P-Trap &
Supplies
by Others
CLEARANCE
HOLE
*17 - 21"
(432 - 533)
4"
(102)
7/8"
(22)
7/8"
(22)
4"
(102)
TRAP FOR WALL OUTLET ONLY
1"
(25)
1-1/2" NPT DRAIN
1" NPT SUPPLIES FROM ABOVE
MUST REDUCE TO 1/2" NOM.
COPPER TUBE ON THESE
CENTERS TO PASS THROUGH
WASHFOUNTAIN
1-1/2" NPT DRAIN
THROUGH WALL
(STUB OUT TO SUIT
TRAP DIMENSIONS)
TRAP
COLD
H
OT
13" R. TOP ACCESS
7-3/8" R. BOTTOM ACCESS
DRAIN THROUGH WALL
WALL
36" BOWL
(914)
4-3/4"
(121)
- Supplies from above
- Vented through wall
off-drain
Type O Drain
(mm)
NOTE: Supply lines for one to two
washfountains should be 1"; for three
washfountains, 1-1/4". For more than
three washfountains, pipe sizes should
be increased proportionately.
*
ADJUSTMENTS TO VERTICAL DIMENSIONS
FOR VARIOUS RIM HEIGHTS
Rim Height Application Adjustment
34" Adult Height ADA, None, as shown
TAS Adult Height
32" TAS Ages 11 thru Subtract 2"
14 or 15, Grades 6
thru 8 or 9
30" TAS Ages 4 thru Subtract 4"
10 or 11, Grades
Pre-K thru 5 or 6 &
Proposed Juvenile
Height ADA
Figure 3