Installation manual
Terreon® Deep Bowl 36" Semi-Circular Washfountain with Air Metering Valve
Installation Instructions TDB3103, WF3203
Bradley Corporation • 215-1479 Rev. G; EN 06-915
52/8/07
Semi-Circular Washfountain Rough-Ins
1" (25mm)
2"
(51mm)
4"
(102mm)
12"
(305mm)*
SEE TABLE
BELOW
MALE 1" NPT SUPPLY LINES
STUB OUT 1" FROM WALL
FINISHED FLOOR
HOT COLD
Figure 1c
* ADJUSTMENTS TO VERTICAL DIMENSIONS
FOR VARIOUS RIM HEIGHTS
Rim Height Application Adjustment
34" Adult Height ADA, TAS Adult Height None, as shown
35" (WF3203)
32" TAS Ages 11 thru 14 or 15, Subtract 2"
Grades 6 thru 8 or 9
30" TAS Ages 4 thru 10 or 11, Subtract 4"
Grades Pre-K thru 5 or 6 &
Proposed Juvenile Height ADA
1-1/2" NPT DRAIN
FROM THE WALL
PEDESTAL
OPENING
AT WALL
9"
(229mm)
34"
(864mm)
RIM
HEIGHT*
SEE TABLE
BELOW