Installation manual
Terreon® Deep Bowl 36" Semi-Circular Washfountain with TouchTime
®
Metering Control
TDB3103, WF3203 Installation Instructions
Bradley Corporation • 215-1579 Rev. C; EN 06-915
12 2/12/07
Touch Time Installation Instructions continued . . .
Step 6: Valve and Electrical Connections for Touch Time
NOTE: Touch Time switch has four wires.
1. Connect the two transformer wires, and the two wires from the solenoid valve to the four wires from the
the Touch Time switch. See Figure 10.
2. Plug the 24 VAC Class II transformer into the 110 VAC GFI outlet.
3. Turn supplies on. Open Check/Stop valves. Open volume control valve completely.
4. Push the Touch Time switch to activate water. Water will turn on when the button is released.
5. If the switch does not activate water, recheck electrical connections.
6. Depress a pushbutton until air is purged from the lines.
TOUCHTIME VALVE WITH THERMOSTATIC MIXING VALVE (SHOWN ) S45-2233
TOUCHTIME VALVE WITH TEMPERED LINE (NOT SHOWN ) S45-2234
NOTE: FLUSH SUPPLY LINES BEFORE MAKING CONNECTIONS.
DO NOT APPLY PIPE SEALANT TO COMPRESSION FITTINGS.
Touch Time Module
(S83-180)
Supply Tube
Transformer
(S83-134)
Circular TT
Module Assembly
Figure 10