Specifications

TDB3104, WF3204 Installation
10 1/10/2013 Bradley • 215-1479 Rev. J; EN 12-00-004
Unit with "O" Drain and Actuator Module
Shown, Also Available with "A" Drain
Restraining Bracket
(140-128)
Top
Cover
Soap
Dispenser
8-5/8"
Tie Rod
Spacer
Coupling Nut
and Set Screw
Module
Cover
4-1/4" Tie Rod
(176-118)
Actuator Module
Assembly
Coupling Nut
and Set Screw
21-5/8" Tie Rod
(176-008A)
Tie Bar
Sprayhead
(S05-054B)
Support Tube
Valve and Tubing Connections -
Air metering Valve
Tie Rod
(176-008A)
Tie Rod Nut
(110-064)
Do not apply pipe sealant
to compression fittings.
Flexible
Hose
(269-2053)
Stop
(S27-340)
Cold
Hot
Air Valve with
Tempered Line (Not
Shown) (S45-2611)
Volume
Control
Air Valve with
Thermostatic Mixing
Valve (Shown)
(S45-2545)
3/8" Tubing
(R68-600014)
To Fitting
(145-105)
1/8" Air Tubing
to Module
(R68-600008)
H
C
A
Loosen Cap Screw about 1/4" (4-6 turns)
and lift up cover (do not remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
6
Adjust the Temperature
C
D
Clean sprayhead if necessary. Adjust the
volume control to control the flow of water.
Attach pedestal access panel with
hardware provided.