Specifications
TDB3104, WF3204  Installation
14  1/10/2013 Bradley • 215-1470 Rev. J; ECN 12-00-004
6
Valve and tubing connections
Flush supply lines before making connections. 
Do not apply pipe sealant to compression fittings.
A
Attach hot and cold flexible supply lines to 
mixing valve assembly, two places. Make 
sure the hot supply is connected to the hot 
inlet on the valve (marked with the letter "H") 
and the cold supply is connected to the cold 
inlet on the valve (marked with the letter "C").
B
Hang valve assembly on pedestal valve 
bracket.
C
Use wire tie to secure valving to valve 
bracket.
Valve Bracket
3/8" Tube from 
Sprayhead
Flexible 
Hosing 
Hot 
Supply
Pedestal 
Rear
Flexible 
Hosing 
Cold 
Supply
Thermostatic 
Mixing Valve
Volume 
Control
D
Turn supplies on. Open stop valves 
completely. Open volume control valve 
completely and check piping installation for 
leaks.
E
Push actuator button until air is purged from 
the lines.