Specifications

Installation TDB3104, WF3204
Bradley • 215-1578 Rev. D; ECN 12-00-004 1/15/2013 5
Rough-In Specifications
(mm)
Type B Drain
- Supplies from above
- Vent through ceiling
off trap inside pedestal
Type A Drain
- Supplies from below
or through wall
- Vent from below or
through wall off-drain
2" NPT Drain Through Floor, Stub
up 3" (76) Above Floor
1/2" Nominal Copper Tubing for Cold
Supply Through Floor (optional),
Stub Up 2-1/2" (64) Above Floor
13" R Top Access
54" (1372) Bowl
7-3/8" R Bottom Access
1/2" Nominal Copper Tubing for Hot
Supply Through Floor (optional),
Stub Up 2-1/2" (64) Above Floor
3-1/4"
(83)
5-1/4"
(133)
4"
(102)
7-5/8"
(194)
7-5/8"
(194)
1/2" nominal copper
tubing supplies
through wall
Trap for Wall Outlet Only
4" (102) Clearance Hole
Drain Through Wall
Supplies Through Wall
12"
(305)
6" to 13-1/4"
(152 to 337)
(mm)
1-1/2" NPT Vent to Ceiling
13" R Top Access
54" (1372) Bowl
7-3/8" R Bottom Access
2" NPT Drain, Stub Out
3" (76) Above Floor
5-1/4"
(133)
WallWall
Vent
Drain Through Floor
1/2" Nominal Copper
Tubing Supply from Above
7/8"
(22)
Hot
Cold
7/8"
(22)
1-1/4"
(32)
Wall
Drain and Supplies Through Floor Trap
Located Below Floor (Optional)
4" (102)