Specifications
Installation TDB3104, WF3204
Bradley • 215-1578 Rev. D; ECN 12-00-004 1/15/2013 15
7
Valve and Electrical Connections for TouchTime
TouchTime switch has four wires.
A
Connect the two transformer wires and the two
wires from the solenoid valve to the four wires
from the TouchTime switch.
B
Plug the 24 VAC Class II transformer into the 110
VAC GFI outlet.
C
Turn supplies on. Open stop valves. Open volume
control valve completely. Check for leaks.
D
Push the TouchTime switch to activate water.
Water will turn on when the button is released.
If the switch does not activate water, recheck
electrical connections.
E
Depress a pushbutton until air is purged from the
lines.
H
C
A
Loosen Cap Screw about 1/4" (4-6 turns)
and lift up cover (do not remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
8
Adjust the Temperature
TouchTime
Module
(S83-180)
Transformer
(S83-134)
Supply
Tube
C
Clean sprayhead if necessary. Adjust the
volume control to control the flow of water.
D
Attach pedestal access panel and kick
plate with hardware provided.