Specifications

Installation TDB3104, WF3204
Bradley • 215-1578 Rev. D; ECN 12-00-004 1/15/2013 11
5a
TouchTime Valve Assembly for A Drain and O Drain Units
without Tie Pipe Option continued...
D
Place the TouchTime module assembly on top of
sprayhead. Rotate until TouchTime module locks in
with tie bar. Drop TouchTime module wires down
the support tube. Make sure TouchTime push
button is facing away from the wall.
Skip to step F for units without soap.
E
For units with soap option, install the spacer, soap
dispenser and cover using the third tie rod (8-5/8"
long) and second coupling nut as shown. Secure
with acorn nut and set screw.
F
Secure TouchTime module cover and top cover with
sprayhead restraining bracket, acorn nut and set
screw.
G
Connect supply stops onto stub-outs. Connect
flexible hoses to supply stops.
Unit with "O" Drain and Actuator Module
Shown, Also Available with "A" Drain
Top
Cover
Soap
Dispenser
8-5/8" Tie Rod
Spacer
Coupling
Nut
Module
Cover
4-1/4" Tie Rod
TouchTime
Module Assembly
(S83-180)
Coupling
Nut
Tie Bar
Sprayhead
(S05-054B)
Standard Support Tube
(S57-005)
TAS/Juvenile Support Tube
(S57-006)
Standard Tie Rod
21-5/8"
Juvenile Tie Rod
18-1/8"