Specifications
Installation TDB3108, WF3208
Bradley • 215-1471 Rev. F; ECN 13-00-001 1/23/2013 5
Rough-In Specifications
(mm)
Type A Drain
Off-line vent with
supplies from below
2" NPT Drain
Through Floor,
Stub up 3" (76)
Above Floor
1" NPT Supplies Through Floor,
Stub Up 2-1/2" (64) Above Floor
1" NPT Supplies From Above Must
Reduce to 1/2" Nominal Copper Tube on
These Centers to Pass Thru Washfountain
54" (1372) Bowl
4"
(102)
7-5/8"
(194)
7-5/8"
(194)
(mm)
Hot Cold
Type O Drain
Off-line vent with
supplies from above
2" NPT Drain
Through Floor,
Stub Up 3" (76)
Above Floor
54" (1372) Bowl
1-1/4"
(32)
Hot Cold
7/8"
(22)
7/8"
(22)
4"
(102)
Supply lines for one to two
washfountains should be 1"; for three
washfountains 1-1/4". For more than
3 washfountains, pipe sizes should be
increased proportionately.
Supply lines for one to two
washfountains should be 1"; for three
washfountains 1-1/4". For more than
3 washfountains, pipe sizes should be
increased proportionately.