Specifications

TDB3108, WF3208 Installation
14 1/23/2013 Bradley • 215-1471 Rev. F; ECN 13-00-001
B
Loosen temperature locking nut with
wrench.
D
Once desired temperature is reached,
tighten nut to prevent temperature change.
C
Using a blade screwdriver, turn the
adjustment stem counterclockwise to
increase the temperature or clockwise to
decrease the temperature.
A
Check the temperature when
approximately 1.0 GPM water flow
is reached and adjust if necessary
(the range of the valve is 95°F–115°F
(35°C–43°C)). To adjust the temperature
follow steps B through F
This valve is NOT factory preset. Upon installation, the temperature of this valve
must be checked and adjusted to ensure delivery of a safe water temperature. Water
in excess of 110°F (43°C) may cause scalding.
6
Adjust the Temperature
E
Clean sprayhead if necessary. Adjust the
volume control to control the flow of water.
F
Attach pedestal access panel and kick
plate with hardware provided.
Temperature
Adjustment Stem
Temperature
Locking Nut