Specifications

Installation TDB3108, WF3208
Bradley • 215-1471 Rev. F; ECN 13-00-001 1/23/2013 13
5
Valve and tubing connections
Flush supply lines before making connections.
For “O” and “B” units (overhead supplies)
skip steps C through E.
A
Connect 1/2" dia. tubing to tee and solenoid
assembly, two places. The male connector
for the valve assembly will remain tight and
leakproof when tubing is cut and installed
properly. Follow the procedures below when
installing tubing to ensure that you achieve a
leakproof seal.
• Using a sharp razor, cut tubing squarely
and remove any burrs. DO NOT pinch or
crush end of tubing.
• Loosen nut on fitting. Moisten end of tube
and push into fitting until it is firmly seated.
Tighten nut to secure tube to fitting (make
sure nut is securely tightened).
• If connector leaks, reseat tubing
according to above procedure. If leaking
persists, replace male connector, or call
your Bradley representative for assistance.
B
Hang valve assembly on pedestal valve bracket.
C
Use wire tie to secure valving to valve bracket.
Valve Bracket
Wire Tie
Pedestal
(1) 1/8" Tube
Connector Tee
Cold Supply
Flexible Hose
Hot Supply
Flexible Hose
(2) 1/8" Air Supply
From Actuator
Module
1/2" Tube
From
Sprayhead
Volume
Control
D
Connect the 1/2" NPT female end of the stop/
check valves to the rough-ins.
G
Check to make sure both Stop/Check valves
and volume control valve is fully open.
E
Attach flexible hosing to thermostatic mixing
valve, two places.
H
Turn on the main water supply and check for
leaking.
F
Insert the filter washers (provided) into the
swivel nut at the end of the supply hoses and
connect to the stop/check valves.
I
Push operating Pushbutton until air is purged
from lines.
Male
Connector
Tubing
Locking
Slope
Gripping
Ridge
Tube
Stop
Sealing
Ring
Release
Button
Valve Assembly
(S08-373)
3/8" NPT x
1/2" O.D. Tube
(269-639)
1/2" Dia. Tube to
Sprayhead
To Actuator
Connector
(2) Places
Volume Control
(S02-045)
Reducer
(169-059)
3/8" Nipple
(113-006EC)
Check Valve
(269-1140)
Flexible
Hose
Filter
Washer
Stop/
Check
Thermostatic Mixing
Valve Assembly
(S67-597)
Air Valve
(S07-044)
Air Valve Timer
Adapter
(198-008)
1/8" Tee
(S53-046)
Tube
Connector
(169-890)