Specifications
Installation TDB3108, WF3208
Bradley • 215-1471 Rev. F; ECN 13-00-001 1/23/2013 11
4b
Air Metering Valve Assembly for B Drain and H Drain Units with
Tie Pipe Option
A
Install hemmed end (not sharp end) of
support tube with gasket onto bowl.
B
Connect 1/2" supply tubing to sprayhead
with 3/8" NPT to 1/2" tube connector and
place sprayhead onto support tube. Run the
tubing down through the support tube and
connect to valve tube connector.
C
Insert the 1-1/2" vent pipe (supplied by
installer) down through the support tube and
thread into vented trap.
Cover
Actuator
Module
Assembly
Sprayhead
Tie Bar
Supply Tube
Section View of
B/H Unit Assembly
Tie Bar Pre-Pack
(S45-056)
Cover
(107-185 (B))
(107-048 (O))
Sprayhead
(S05-054)
Drain
(S45-273)
Terreon
®
Deep Bowl
(Part No. Varies with color
of bowl. Contact your local
Bradley Rep for assistance)
Access Panel
(186-1191)
Valve Assembly
(S08-373)
Pedestal Assembly
(S17-242)
1/2" Supply
Tube
Vented Trap
(111-024)
Support
Tube Gasket
(125-011)
Support Tube
STD (S57-005)
TAS/JUV (S57-006)
Actuator Module
Assembly (S65-132)
B/H