Installation manual

Terreon® 54" Circular Deep Bowl Washfountain with Air Metering Valve
TDB3108, WF3208 Installation Instructions
Bradley Corporation • 215-1471 Rev. E; EN 06-915B14 4/6/2007
SUPPORT TUBE
GASKET
125-011
SUPPORT TUBE
(STD) S57-005
(JUV) S57-006
PRE-PACK
S45-1466
VENTED TRAP
111-024
TIE BAR
PRE-PACK
S45-056
PEDESTAL ASSY.
S17-242
COVER
107-185 (B)
107-048 (H)
ACTUATOR MODULE ASSY.
1/2" SUPPLY TUBE
SPRAYHEAD
S05-054
DRAIN
S45-273
VALVE ASSY.
S08-373
ACCESS PANEL
186-1191
TERREON® DEEP BOWL
(ADA bowl shown, classic bowl
is optional) Part No. varies with color
of bowl. Contact your Bradley Rep.
for assistance).
B/H
(B shown)
S65-132 (See Illustration on page
18 for actuator components).
COVER
SECTION VIEW OF
B/H UNIT ASSEMBLY
SPRAYHEAD
ACTUATOR
MODULE
ASSY.
TIE
BAR
SUPPLY
TUBE
Installation Instructions continued . . .
Step 4b: Air Metering Valve assembly for B and H and units with Tie Pipe option
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 8).
2. Connect 1/2" supply tubing to sprayhead with 3/8" NPT to 1/2" tube connector and place spray-
head onto support tube. Run the tubing down through the support tube and connect to valve tube
connector.
3. Insert the 1-1/2" vent pipe (supplied by installer) down through the support tube and thread into
vented trap.
Figure 8