Installation manual
Terreon® 54" Circular Deep Bowl Washfountain with Air Metering Valve
Installation Instructions TDB3108, WF3208
Bradley Corporation • 215-1471 Rev. E; EN 06-915B 134/6/2007
Installation Instructions continued . . .
4. Place the actuator module assembly on top of sprayhead. Rotate until actuator module locks in
with tie bar. Drop two 1/8" diameter tubes down to valve assembly and connect to the air valve.
NOTE: Skip to number 5 for units without soap.
• For units with soap option, install the spacer, soap dispenser and cover using the third tie rod
(8-5/8" long) and second coupling nut as shown (see Figure 7). Secure with acorn nut and set
screw.
5. Secure actuator module cover and top cover with acorn nut and set screw.
6. FOR O UNIT: Install 1/2" nominal copper tubing supply lines (pass them through holes in
cover down through support column) and connect to stops using suitable fittings.
Figure 7
TOP COVER
SPRAYHEAD
S05-054
SUPPORT TUBE
(STD.) S57-005
(JUV.) S57-006
MODULE
COVER
COUPLING NUT
SPACER
ACTUATOR
MODULE
ASSEMBLY
S65-132
SOAP
DISPENSER
TIE ROD
21-5/8" (STD.)
18-1/8" (JUV.)
TIE BAR
UNIT WITH “O” DRAIN AND ACTUATOR MODULE
SHOWN, ALSO AVAILABLE WITH “A” DRAIN
COUPLING
NUT
8-5/8"
TIE ROD
4-1/4"
TIE ROD