Installation manual

Terreon® 54" Circular Deep Bowl Washfountain with TouchTime
®
Control
TDB3108, WF3208 Installation Instructions
Bradley Corporation • 215-1577 Rev A; EN 06-915B18 4/6/2007
Touch Time Installation Instructions continued . . .
Step 6: Valve and Electrical Connections for Touch Time
1. Mount the terminal block in a convenient location using the hook and loop fastener supplied.
Make sure all wires will reach.
NOTE: Each Touch Time switch has four wires.
2. Connect the two transformer wires, and the two wires from the solenoid valve to the terminal block.
Connect the eight wires from the two Touch Time switches. See Figure 12.
3. Plug the 24 VAC Class II transformer into the 110 VAC GFI outlet.
4. Turn supplies on. Open Check/Stop valves. Open volume control valve completely.
5. Push the Touch Time switch to activate water. Water will turn on when the button is released.
6. If the switch does not activate water, recheck electrical connections to the terminal block.
7. Depress a pushbutton until air is purged from the lines.
Touch Time Module
(S83-179)
Supply Tube
Transformer
(S83-134)
Circular TT
Module Assembly
Figure 12