Installation manual
Terreon® 54" Circular Deep Bowl Washfountain with with TouchTime
®
Control
Installation Instructions TDB3108, WF3208
Bradley Corporation • 215-1577 Rev A; EN 06-915B 154/6/2007
Installation Instructions continued . . .
4. Place the TouchTime module assembly on top of the sprayhead. Drop TouchTime module wires
down to the valve assembly.
NOTE: Skip to number 5 for units without soap.
• For units with soap option, slide the spacer and soap dispenser over the 1-1/2" pipe.
5. Position the upper tie bar slightly below the module (see Figure 8 inset on previous page) or
soap dispenser (see Figure 9) and fasten securely to vent pipe with set screws provided. Secure
top cover to tie bar with two cap screws provided.
6. FOR B UNIT: Install 1/2" nominal copper supply lines (pass through holes in cover and
through support column) and connect supply lines to stops using suitable fittings.
Figure 9
TOP COVER
SPRAYHEAD
S05-054
SUPPORT TUBE
S57-005 (STD.)
S57-006 (JUV.)
MODULE
COVER
SPACER
TOUCHTIME
MODULE
ASSEMBLY
S83-179
SOAP
DISPENSER
TIE BAR
UNIT WITH “H” DRAIN AND ACTUATOR MODULE
SHOWN, ALSO AVAILABLE WITH “B” DRAIN