Installation manual

Express® Lavatory System SS-Series
SS-3N/IR/STD, SS-3N/IR/WH Installation Instructions
6 4/16/04 Bradley Corporation • 215-1493 Rev. B; EN 03-808A
RIM HEIGHT
VERTICAL HEIGHT
ADJUSTMENTS
"A" THROUGH "F"
FIXTURE STYLE
34"
NONE STANDARD HEIGHT
34" NONE WALL HUNG
32" SUBTRACT 2" TAS,GRADES 6 THROUGH 8/9
31" SUBTRACT 3" JUVENILE HEIGHT
30" SUBTRACT 4" TAS,PRE-K THROUGH 5/6
CODE DESCRIPTION QTY.
"A"
3/8" BOWL WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 lbs.
2
"B"
3/8" MAIN FRAME WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 lbs.
6
"C"
3/8" BASE FRAME WALL ANCHORS, STANDARD FRAME OPTION ONLY.
2
"D"
1/2" NPT HOT/COLD SUPPLIES, STUB OUT 2" FROM WALL.
2
"E" 1-1/2" NPT DRAIN, STUB OUT 2" FROM WALL.
1
"F"
110V GFCI PROTECTED ELEC. OUTLET.
1
CHART 1
CHART 2
Figure 1
SS-3N/IR Express® Lavatory System Dimensions
* RECOMMENDED 240V/208V OR 277V ELECTRICAL
BOX LOCATION 4"L x 4"W x 8"H
18"
(457mm)
27-1/2" (699mm)
MOUNTING FOR STANDARD AND WALL HUNG HEIGHTS ARE SHOWN
F
A
A
B
B
B
B
B
B
C
C
D
D
E
RIM HEIGHT
SEE CHART 1
TEMPERED
SUPPLY
24-3/8"
(619mm)
8"
(203mm)
13"
(330mm)
2-3/4"
70mm)
4"
(102mm)
24-3/8"
(619mm)
32"
(813mm)
28-3/4"
(720mm)
15"
(381mm)
5-5/8"
(143mm)
24"
(610mm)
34"
(864mm)
3-1/2" (89mm)
COLD
SUPPLY
FLOOR
OPTION #1*
23"
(584mm)
OPTION #2*
38-1/2" (978mm)
REF. DIM.
38-1/2" (978mm)
REF. DIM.