Installation manual

Installation Instructions
continued . . .
Step 2: Mounting frame to wall
1. Using a T20 Torx key, remove the six #10-24 flat head Torx screws and #10 finish washers
securing the access panel to the main frame, and remove the panel (see Figure 2).
2. Position the main frame against the wall, ensuring that it is level.
IMPORTANT: Anchoring the frame to a wall that is
not
flat may cause the frame to
bend, making it difficult to reinstall the access panels.
3. Ensure that the back of the main frame is flat against the wall.
4. Once you have positioned the
main frame such that it is level
and flat against the wall, use
the 3/8" bolts and 1" min. O.D.
washers to mount the main
frame to the wall (Figure 3).
5. When mounting the standard
height frame, mount the scuff
base to the wall at the same
time (using two additional 3/8"
bolts and washers mentioned in
Step 1, procedure #4 on page 5)
(see Figure 3).
7
Express® Lavatory System SS-Series
Installation Instructions SS-2N/IR/STD, SS-2N/IR/WH
Bradley Corporation • 215-1497 Rev. B; EN 03-808A 4/16/04
*
*
*
*
*
*
3/8" WALL ANCHORS
(4) PLACES
3/8" WALL ANCHORS
(2) PLACES
STANDARD HEIGHT
FRAME ONLY
MAIN FRAME
SCUFF BASE FRAME
STANDARD HEIGHT
FRAME ONLY
ACCESS PANEL
SCUFF PANEL
(STANDARD
HEIGHT FRAME ONLY)
MAIN FRAME
Figure 3
Figure 2