Installation manual
6
Express® Lavatory System SS-Series
SS-2N/IR/STD, SS-2N/IR/WH Installation Instructions
4/16/04 Bradley Corporation • 215-1497 Rev. B; EN 03-808A
RIM HEIGHT
VERTICAL HEIGHT
ADJUSTMENTS
"A" THROUGH "F"
FIXTURE STYLE
34"
NONE STANDARD HEIGHT
34" NONE WALL HUNG
32" SUBTRACT 2" TAS,GRADES 6 THROUGH 8/9
31" SUBTRACT 3" JUVENILE HEIGHT
30" SUBTRACT 4" TAS,PRE-K THROUGH 5/6
CODE DESCRIPTION QTY.
"A"
3/8" BOWL WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 lbs.
2
"B"
3/8" MAIN FRAME WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 lbs.
4
"C"
3/8" BASE FRAME WALL ANCHORS, STANDARD FRAME OPTION ONLY.
2
"D"
1/2" NPT HOT/COLD SUPPLIES, STUB OUT 2" FROM WALL.
2
"E" 1-1/2" NPT DRAIN, STUB OUT 2" FROM WALL.
1
"F"
110V GFCI PROTECTED ELEC. OUTLET.
1
CHART 1
CHART 2
SS-2N/IR Express® Lavatory System Dimensions
3-1/2"
(89mm)
20"
(508mm)
25-3/4"
(654mm)
32"
(813mm)
23-1/2"
(597mm)
9-3/8"
(238mm)
4"
(102mm)
3"
(76mm)
13-1/4"
(337mm)
15"
(381mm)
F
A
A
B
BB
B
C
C
D
D
E
23-1/2"
(597mm)
9-3/8"
(238mm)
4"
(102mm)
TEMPERED
SUPPLY OPTION
* OPTION 1 - RECOMMENDED 240V/208V OR 277V
ELECTRICAL BOX LOCATION (4"L x 4"W x 8"H)
COLD SUPPLY
19"
(483mm)
FLOOR
2" (51mm)
13"
(330mm)
22"
(559mm)
28-3/4"
(730mm)
C
L
OPTION #1*
OPTION #2**
** OPTION 2 - RECOMMENDED 240V/208V OR 277V
ELECTRICAL BOX LOCATION (4"L x 4"W x 4"H)
Figure 1