Installation manual
10
Express® Lavatory System SS-Series
SS-2N/IR/STD, SS-2N/IR/WH Installation Instructions
4/16/04 Bradley Corporation • 215-1497 Rev. B; EN 03-808A
Installation Instructions
continued . . .
Step 5: Connecting optional hot water heater
NOTE: 240/208 or 277 voltage is
required for hot water heater. Refer to
the installation manual provided with
the hot water heater for further
installation information.
1. Remove the cover from the water
heater. Attach the bracket to the
cover with the two screws, nuts and
washers, then reattach the cover
(see Figure 6a).
2. Hang the water heater on the right
side frame member (see Figure 6b).
3. Connect the 1/2" flexible hose from
the cold water supply stub-out to
the hot water heater inlet.
4. Connect the 1/2" flexible hose from
the hot water heater outlet to the
supply inlet on the solenoid valve
assembly.
COLD WATER
SUPPLY
WATER HEATER
(269-1767)
BRACKET
(140-950)
OUTLET
INLET
SOLENOID VALVE
ASSEMBLY
FLEX. HOSE FROM
WATER HEATER OUTLET
TO SOLENOID VALVE
ASSEMBLY
FLEX. HOSE FROM
COLD WATER SUPPLY
TO WATER HEATER INLET
#8-32 x 3/4"
ROUND HEAD
MACHINE SCREW
BRACKET
#8 WASHER
#8 NUT
WATER
HEATER
BASE
WATER
HEATER
COVER
Figure 6b