Specifications
Classic Circular 36"/54" Washfountain with Air Valve Control
Installation Instructions WF2605, WF2608 Terrazzo – WF2705, WF2708 Stainless Steel
5Bradley Corporation • 215-1521 Rev. D; EN 06-915B 4/6/2007
Rough-In Specifications
Rough-In Notes For All Models:
1. All pipes and fittings not furnished by
 Bradley are shown in broken lines.
2. Supply lines for one to two washfountains should
 be 1"; for three washfountains 1-1/4"; for more 
 than three washfountains, pipe sizes should be
 increased proportionately.
3. Overhead supplies must be reduced to 1/2"
 copper tube to pass through support tube.
4. Check valve inlets are 1/2" NPT.
5. Dimensions shown in parentheses are millimeters.
 Remote mounting of transformer with 24 VAC electrical
 supply to washfountain is recommended (this conduit 
 location is only a recommendation). See local electrical
 codes before roughing in.
*
NOTE: UPC and IPC restrict the vertical
distance from the fixture outlet to the trap
weir to not more than 24". Check state and 
local codes for variances.
Type A 
Off-line vent with
supplies from below
Type B 
Centrally rising vent with
supplies from above
TOP VIEW
1" NPT SUPPLIES THROUGH
FLOOR: STUB UP 2-1/2" (64) 
ABOVE FLOOR
7-5/8"
(194)
7-5/8"
(194)
COLD
HOT
4"
(102)
2-1/2"
(64)
2" NPT DRAIN:
STUB UP 3" (76)
ABOVE FLOOR
36" (914) BOWL
54" (1372) BOWL
5" 
CONDUIT
LOCATION
*
1" NPT SUPPLIES FROM ABOVE
MUST REDUCE TO 1/2 NOM. 
COPPER TUBE ON THESE CENTERS
TO PASS THRU WASHFOUNTAIN
7/8"
(22.2)
7/8"
(22.2)
COLD
HOT
1-1/2" NPT VENT 
TO CEILING
2" NPT DRAIN: 
STUB UP 3" (76) 
ABOVE FLOOR
4"
(102)
36" (914) BOWL
54" (1372) BOWL
1-1/4
"
(32)
5" 
(127)
CONDUIT
LOCATION
*
TOP VIEW