Specifications

Classic Circular 36"/54" Washfountain with Touch Time™ Control
WF2605, WF2608 Terrazzo – WF2705, WF2708 Stainless Steel Installation Instructions
16 4/6/2007 Bradley Corporation • 215-1518 Rev. C; EN 06-915B
Touch Time Installation Instructions continued . . .
Step 7: Valve and Electrical Connections for Touch Time
1. Mount the terminal block in a convenient location using the hook and loop fastener supplied.
Make sure all wires will reach.
NOTE: Each Touch Time switch has four wires.
2. Connect the two transformer wires, and the two wires from the solenoid valve to the terminal block. (The
eight wires from the two Touch Time switches which were previously connected in Step 5). See Figure 11.
3. Plug the 24 VAC Class II transformer into the 110 VAC GFI outlet.
4. Push the Touch Time switch to activate water. Water will turn on when the button is released.
5. If the switch does not activate water, recheck electrical connections to the terminal block.
To 1/2" Supply
1/2" Supply
Manual Mixing Valve
(S01-038)
TMA Optional (S01-525)
Touch Time Module
(S83-179)
Supply Tube
Transformer
(S83-134)
Circular TT
Module Assembly
Figure 11