Specifications
Classic Circular 36"/54" Washfountain with Touch Time™ Control
Installation Instructions WF2605, WF2608 Terrazzo – WF2705, WF2708 Stainless Steel
11Bradley Corporation • 215-1518 Rev. C; EN 06-915B 4/6/2007
Installation Instructions continued . . .
Step 5a: Installing Supplies with Optional Soap Dispenser for A/O drain units
NOTE: See Step 5b on page 13 for Type B/H drain units.
NOTE: For models with optional paper towel dispensers, tie pipe assembly, or shroud, see separate
instruction sheets and Step 4b for units with type B/H drain.
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl as shown in Figure 8
on page 12.
2. Connect 1/2" supply tubing to sprayhead as shown in Figure 7. Follow the procedures below
when installing 1/2" tubing into sprayhead to ensure that you achieve a leakproof seal.
• Using a sharp knife, cut tubing squarely and remove any burrs. DO NOT pinch or crush end
of tubing.
• Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated.
Tighten nut to secure tube to fitting (make sure nut is securely tightened).
• If connector leaks, reseat tubing according to above procedure. If leaking persists,
replace male connector, or call your Bradley representative for assistance.
3. Place sprayhead with 1/2" tubing onto support tube as shown in Figure 8 on page 12. Run tubing
down through support tube.
4. Assemble the lower tie rod (the longer threaded rod), upper tie bar (notched at corners), lower tie
bar, tie rod nut, and coupling nut, then attach the 4-1/4" tie rod to coupling nut as shown in
Figure 8.
5. Connect the eight wires from the two Touch Time switches in the Touch Time module assembly
to the terminal block as shown in Figure 11 on Page 16.
6. Place Touch Time module assembly on top of sprayhead. Rotate until Touch Time module locks
in with module tie bar. Drop the terminal block with the wires attached down into the pedestal.
7a. FOR UNITS WITH SOAP OPTION: Install the spacer, soap dispenser and cover using the
coupling nut, soap tie rod (8-5/8" long) and second coupling nut as shown (see Figure 8). Secure
with acorn nut and socket head set screw.
7b. FOR UNITS WITHOUT SOAP OPTION: Secure module cover and dispenser cover with
acorn nut and socket head set screw.
8. Continue installation with Step 6 on page 15.
NUT
TUBING
MALE
1/2" TUBE
CONNECTOR
269-626
SPRAYHEAD
Figure 7
TUBING