Specifications
Classic Circular 36"/54" Washfountain with Infrared Control
Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
15Bradley Corporation • 215-1449 Rev. D; EN 06-915B 4/6/2007
Installation Instructions continued . . .
Step 6: Installing the valve assembly
NOTE: Flush supply lines before making connections.
1. Connect the stop-strainer-check valves, mixing valve, volume control valve, and solenoid valve
assembly as shown in Figure 10b.
2. For overhead supply lines, install 1/2" nominal copper tubing by passing lines through holes in
the dispenser cover and down through the support tube.
3. Install the valving assembly, using suitable fittings, to the supplies as shown in Figure 10b at the
approximate height indicated in Table 2.
4. Connect the 1/2" plastic tubing from the sprayhead to the tube connector on the solenoid valve.
Step 7: Electrical Wiring Connections for Infrared Control
NOTE: Refer to Figure 8 on page 12 for installation of unit with Type A or O drain. Refer to Figure 9
on page 14 for installation of unit with Type B or H drain.
NOTE: Refer to Figure 10b on page 16 for wire connections.
1. Connect the wires with the female connectors from the infrared module to the solenoid valve.
2. Connect the wires with the male connectors from the infrared module to the transformer wires.
3. Plug the 24 VAC Class II transformer into the 110 VAC GFI outlet.
4. Turn the water supply on and check for leaks and adequate water flow. Replace the access panels
on both sides of the washfountain.
Window
(269-832)
Module Cover Assembl
y
(S04-112)
Sensor
(S83-039)
Sensor Bracket
(140-718)
IR Module Assembly
(S83-043)
Figure 10a