Specifications

Classic Circular 36"/54" Washfountain with Infrared Control
Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
13Bradley Corporation • 215-1449 Rev. D; EN 06-915B 4/6/2007
Installation Instructions continued . . .
Step 5b: Installing Supplies with Optional Soap Dispenser for B/H drain units
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl as shown in Figure 9
on page 14.
2. Connect 1/2" supply tubing to sprayhead as shown in Figure 7 on page 11. Follow the
procedures below when installing 1/2" tubing into sprayhead to ensure that you achieve a
leakproof seal.
Using a sharp knife, cut tubing squarely and remove any burrs. DO NOT pinch or crush end of
tubing.
Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated. Tighten
nut to secure tube to fitting (make sure nut is securely tightened).
If connector leaks, reseat tubing according to above procedure. If leaking persists, replace male
connector, or call your Bradley representative for assistance.
3. Place sprayhead with 1/2" tubing onto support tube as shown in Figure 9. Run tubing down
through support tube.
4. Place infrared module assembly on top of sprayhead.
5. Drop two infrared module wires down into the pedestal.
6. Insert the 1-1/2" vent pipe (supplied by installer, see page 4 for length) through the infrared
module, sprayhead, and support tube.
7. Connect to the vented trap provided.
8a. FOR UNITS WITH SOAP OPTION: Place the soap dispenser gasket, spacer, soap dispenser,
and cover in position on top of infrared module (see Figure 9). Slide tie bar over 1-1/2" vent pipe
1/2" below top of soap dispenser lid and secure with the two cap screws included with the tie
bar. Slide the dispenser cover over 1-1/2" vent pipe and secure with the two cap screws included
with the tie bar.
8b. FOR UNITS WITHOUT SOAP OPTION: Slide tie bar over 1-1/2" vent pipe, 1/2" below top
of infrared module and secure with set screws. Slide the dispenser cover over 1-1/2" vent pipe
and secure with the two cap screws included with the tie bar.
9. Connect vent pipe to vent through ceiling with pipe union.
10. Continue installation with Step 6 on page 15.